lasercutter2
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
lasercutter2 [2018-07-21 22:06] – [Safety] alfie | lasercutter2 [2018-11-21 20:48] – tim | ||
---|---|---|---|
Line 1: | Line 1: | ||
====== Laser Cutter #2 ====== | ====== Laser Cutter #2 ====== | ||
- | NOT YET IN SERVICE. | + | TRAINING REQUIRED BEFORE USE.\\ |
- | (Note: | + | (Note: |
Model JD90125\\ | Model JD90125\\ | ||
Line 180: | Line 180: | ||
2018-07-19: | 2018-07-19: | ||
* The bed level was checked and it's within 1mm all over. The axes were checked and they' | * The bed level was checked and it's within 1mm all over. The axes were checked and they' | ||
+ | |||
+ | 2018-09-22: | ||
+ | * Tube #2 (from Smoke and Mirrors) installed. All mirrors realigned to a reasonable (but not perfect) standard. | ||
===== Other Specifications (for maintenance) ===== | ===== Other Specifications (for maintenance) ===== | ||
Water tubing: silicone, 12mm OD, 8mm ID, 2mm wall\\ | Water tubing: silicone, 12mm OD, 8mm ID, 2mm wall\\ | ||
- | Chiller: CW-3000\\ | + | Chiller: CW-5200\\ |
Air assist compressor: Hailea ACO-328\\ | Air assist compressor: Hailea ACO-328\\ | ||
Air assist tubing: silicone, 12mm OD, 8mm ID, 2mm wall\\ | Air assist tubing: silicone, 12mm OD, 8mm ID, 2mm wall\\ | ||
Line 196: | Line 199: | ||
* {{ : | * {{ : | ||
* {{ : | * {{ : | ||
- | * {{ :cw-3000.pdf | CW-3000 Chiller Manual }} ({{ :cw-3000-2.pdf | alternative version | + | * {{ :cw-5000_5200_industrial_chiller_user_manual.pdf | CW-5200 Chiller Manual }} |
+ | * {{ :cw-5000_5200_industrial_chiller_maintenance_manual.pdf | CW-5200 Maintenance Manual | ||
* {{ : | * {{ : | ||
* {{ : | * {{ : |
lasercutter2.txt · Last modified: 2023-12-24 13:36 by simon